When selecting force-controlled equipment, descriptions such as "force control accuracy ±0.1 N," "accuracy ±0.1% FS," or "high force control repeatability" are common. Smaller numbers appear better at first glance, yet without knowing what is being evaluated, how it is measured, and under what full-scale range and operating conditions, it is difficult to gauge a system's true capability—let alone compare different products directly.
The key to evaluating force control performance is not asking "what is the number" first, but clarifying: does this number represent "accuracy" or "stability"?
"Accuracy" and "Stability" Are Two Distinct Capabilities
A force control system generally needs to be evaluated across at least two dimensions:
| Evaluation Dimension | Core Question | Engineering Meaning |
|---|---|---|
| Static Force Control Error | How much does actual output force deviate from target force? | Whether the system can accurately hit the force setpoint |
| Force Control Repeatability | How close are multiple outputs under identical conditions? | Whether batch operation results remain stable and consistent |
For instance, if the target force is 10 N and repeated outputs consistently cluster around 10.5 N, the system has good repeatability, yet still carries an offset of about 0.5 N from the target. Conversely, if repeated outputs fluctuate between 9.6 and 10.4 N, the average may be close to 10 N, but individual cycles are not sufficiently stable.
Therefore, a single accurate reading does not prove batch stability, and tightly grouped readings do not guarantee target accuracy. "Accuracy" and "stability" must be tested and specified separately.
Why Can't You Compare a Single "Accuracy" Number Alone?
First, definitions of "force control accuracy" vary across documentation. Some refer to the deviation between actual output and target setpoint, others quote standalone force sensor accuracy, and still others label repeatability as "repeated force control accuracy." Similar terminology does not mean identical evaluation objects or calculation methods.
Second, units and calculation baselines affect interpretation. ±0.1 N expresses an absolute force value, whereas ±0.1% FS typically denotes a percentage of full scale. Under consistent definitions, ±0.1% FS equals ±0.01 N on a 10 N range, versus ±0.1 N on a 100 N range. Comparing percentages without checking full-scale capacity can lead to completely misleading conclusions.
Furthermore, target force, loading direction, mounting orientation, number of cycles, metrology equipment, ambient environment, and mechanical structure all influence results. Numerical values are comparable only when evaluation targets, methods, and conditions are aligned.
How Should Force Control Accuracy Grades Be Determined?
Determining an accuracy grade requires establishing a complete testing procedure rather than taking nominal datasheet numbers at face value:
- Define the device under test.Confirm the exact model, sensor capacity, mechanical configuration, and control parameters—avoid extrapolating one configuration's results to an entire product family.
- Define target forces and test ranges.Performance can differ across low, mid, and near-full-scale force regions; a single setpoint cannot represent all operating conditions.
- Standardize test conditions.Include mounting orientation, loading method, warm-up state, ambient conditions, sampling rate, and reference measurement instruments.
- Conduct multiple repeated trials.Record each individual output and retain raw data rather than reporting only a summary figure.
- Calculate error and repeatability separately.Evaluate both the deviation from the target setpoint and the dispersion across repeated trials; never substitute one metric for the other.
- Assign grades according to an explicit methodology.Grades must map to clear metric definitions, formulas, and threshold boundaries. Without documented test conditions and calculations, a stated grade cannot be verified.
Are There Reference Standards Available?
T/GDRA 013-2024, "Test Methods for Static Performance of Force Control of Industrial Robots," is an association standard covering industrial robot force control systems and force-controlled robots. It specifies test conditions, test procedures, calculation formulas, and reporting requirements, establishing separate evaluation and grading methods for force control error and force control repeatability.
The value of this standard lies in providing a unified benchmark for "how to measure, how to calculate, and how to report," making test results across products easier to audit and compare. In practical application, engineers should still verify consistency in tested model, range, target force, mounting orientation, and test conditions.
Does a High Grade Guarantee Success in Actual Processes?
Not necessarily. Standard grades primarily reflect how accurate and repeatable a system is under prescribed static test conditions—they cannot capture every aspect of real-world production dynamics.
In precision press-fitting, compliant assembly, polishing, or tactile testing, engineers must also examine contact overshoot, response time, vibration, and force tracking capability, alongside the effects of speed, payload, mounting orientation, fixture stiffness, and part-to-part variation. Low static force control error under lab conditions does not guarantee zero overshoot during high-speed contact, nor does good static repeatability guarantee identical behavior across all speeds and payloads.
Hence, grades serve well as a foundational benchmark for comparison, while final selection must return to the actual process: verifying whether the equipment consistently meets requirements under real cycle times, tooling, and workpieces.
Note also that force sensor accuracy is merely the measurement foundation. Signal acquisition, control loop period, algorithm tuning, motor drive, mechanical friction, transmission backlash, and structural stiffness all shape full-system performance. Likewise, position repeatability measures consistency in reaching a spatial target and is not equivalent to force control repeatability.
RobustMotion SoftForce® ®precision force-controlled electric actuators employ real-time force feedback to form a true closed loop. During selection, always cross-check manual specifications against model, sensor capacity, target force, speed, payload, and process requirements, and validate performance through application testing.
A truly meaningful force control grade is never an isolated number on a spec sheet—it is a testable, verifiable, and comparable result obtained under clearly defined objects, conditions, and methodologies.