MagiFloater
Published:
Keywords: closed-loop force control, precision force control, SoftForce, force sensor, control loop, response speed, servo control
Abstract: This article takes a detailed look at the three core factors that determine the final performance: the mechanical system, sensor performance and control-loop efficiency. It explains how RobustMotion’s SoftForce® technology fundamentally resolves the contradiction between response speed and stability through integrated system design and high-speed cooperative algorithms, thereby revealing what is truly required to achieve real high-performance force control.
On the road toward precision force control, many users assume that simply adding a force sensor to an actuator delivers “full closed-loop force control” and thus the desired performance. In practice, however, the force control behavior of many systems built this way (accuracy, response speed, stability) leaves much to be desired.In reality, the final performance of a high-performance full closed-loop force control system is not determined by any single component, but by three core factors working together: the mechanical system, sensor performance and control-loop processing efficiency.

Matching Sensor Performance with the Mechanical System
Sensor performance is the perceptual foundation of the entire closed-loop system. If the sensor itself cannot provide accurate and timely force feedback, even the most powerful controller can do nothing. Key indicators include:
Accuracy and repeatability:A low-accuracy sensor may report force values far from the true value; poor repeatability means that the same force yields a different result every time. A controller that regulates on such inaccurate and unstable data will inevitably produce chaotic output.
Sampling rate:That is, how many independent force readings the sensor can provide per second. With a low sampling rate, the controller only receives discrete data points and cannot know how the force actually changes between them, which is fatal in high-speed dynamic applications.
Integration with the mechanical structure:Where and how the sensor is mounted is also critical. If the mechanical structure has significant play or elastic deformation, the force measured by the sensor cannot truly reflect the contact force at the end effector, which likewise degrades control performance.
Control-Loop Processing Efficiency
This is the core that determines force control performance, and the key to the gap between different approaches. Once a qualified sensing and mechanical system is in place, how the system uses the sensor data directly determines the final control result.
The common “actuator + external sensor + general-purpose controller/PLC” approach on the market has a fundamental bottleneck: the enormous latency caused by external loop computation. From the sensor detecting a force change, to the data being transmitted to the controller, to the controller completing the calculation and issuing a new motion command, the whole process is a long relay race. This latency means the controller is always judging based on outdated force information. As speed increases, the impact of this latency is amplified and the system becomes prone to oscillation.
RobustMotion SoftForce® Precision Force Control Technology
RobustMotion’s SoftForce® precision force control technology solves this problem at the root through integrated system design. We also use a high-precision end-of-effector force sensor, but the core advantages are:
Deep integration and high-speed cooperation:We have integrated a high-rigidity mechanical system, a high-precision force sensor, a high-speed controller and a drive into one design, communicating over an internal high-speed bus. This eliminates the latency caused by the external relay race.
In-house algorithms and an extremely high response frequency:Our self-developed SoftForce® algorithm runs efficiently at an extremely high closed-loop processing frequency, compressing system response time to the microsecond level.
This extreme processing speed means the controller can respond and adjust almost at the very instant the force occurs. It therefore never needs to compromise performance by lowering gain or adding filtering, and can achieve high stability while maintaining high gain (high response), perfectly resolving the contradiction between speed and stability.High-performance full closed-loop force control is by no means a simple addition of “actuator + sensor”. It depends on a high-quality mechanical and sensing system, but the more decisive factor is the computation speed and cooperative efficiency of the entire control loop. Only when the controller can process sensor feedback fast enough and work seamlessly with the mechanical system can closed-loop force control truly deliver its inherent advantages of high accuracy, high response and high stability.
Frequently Asked Questions
Q1: Why does combining a high-precision force sensor with an ordinary servo actuator often produce poor force control results? A: The core bottleneck is control-loop latency. External communication and computation among sensor, controller and actuator take too long, so the controller always regulates on outdated force data, which in high-speed dynamic applications very easily triggers oscillation or loss of control.
Q2: How should we understand that SoftForce® technology achieves both high response and high stability? A: The key lies in microsecond-level system response speed. Extremely low latency allows the controller to react to force changes almost instantaneously without reducing control gain or adding filtering to maintain stability, so it keeps high response capability while ensuring a high degree of system stability.
Q3: When selecting a precision force control solution, besides sensor accuracy, which parameters deserve extra attention? A: Pay close attention to the system’s closed-loop update frequency or response time. This parameter directly reflects the processing efficiency of the control loop and is the key indicator that distinguishes a high-performance integrated force control system from an ordinary assembled solution.











